Ceiling panels with increased thermal resistance 105.06/C
Ceiling panels with increased thermal resistance are used for the construction of cold storage boxes and thermochambers. In these areas, temperature and pressure according to the customer's requirements are maintained. The whole system of connecting panels to each other and to other components (i.e. door casings, ceiling panels, anchoring to the floor) is designed in such a way as to eliminate thermal bridges and minimise heat transfer.
This panel system also contains other elements for the construction of complete boxes: Doors with increased thermal resistance and Partition panels with increased thermal resistance.
TECHNICAL DATA
Panel type |
---|
Ceiling panels without reinforcements with increased thermal resistance |
Panel thickness |
---|
102 mm |
122 mm |
62 mm |
82 mm |
Panel width |
---|
1190 mm |
560 mm |
Preferred width W 1190 mm, 560 mm.It is possible to order atypical panel dimensions: min. dimension 300 mm, max. dimension 1190 mm. |
Panel length |
---|
3000 mm |
Minimum length H 300 mm. Maximum length 4000 mm. Length according to customer's requirements - atypical. |
Filler |
---|
Atypical |
Styrofoam |
Panel installation |
---|
installation of panels not included in delivery |
installation of panels directly 1 pc [(M8 threaded bar, supporting metal sheet, TEX 4.8) x 1 - total number of pieces for panel] |
installation of panels directly 2 pcs[(M8 threaded bar, supporting metal sheet, TEX 4.8) x 2 - total number of pieces for panel)] |
installation of panels directly 3 pcs [(M8 threaded bar, supporting metal sheet, TEX 4.8) x 3 - total number of pieces for panel] |
Atypical |
Facing hue and material - standard on the visible side (bottom side) |
---|
galvanized metal sheet, hue RAL 9002 |
galvanized metal sheet, hue RAL 9016 |
Stainless steel AISI 304 |
Powder coating (Komaxit), hue RAL |
Facing hue and material - on the top side as standard |
---|
galvanized, hue RAL 9016 |
Atypical design |
---|
Type design |
Atypical design |
Type design 0 - Unique specification out of offered versions Atypical design Q - atypical design that cannot be uniquely specified by a code |